47
6.3
Commissioning via FOUNDATION Fieldbus
Note the following points:
• The files required for commissioning and network configuration can be obtained as described on
• The device is identified by the FOUNDATION Fieldbus in the host or configuration system via
the device ID (DEVICE_ID). The DEVICE_ID is a combination of the manufacturer ID, device
type and device serial number. It is unique and can never be duplicated.
The DEVICE_ID of the Prosonic Flow 93C is composed as follows:
Commissioning
The following description allows step-by-step commissioning of the measuring device and all the
necessary configuration for the FOUNDATION Fieldbus:
1.
Switch on the measuring device.
2.
Note the DEVICE_ID on the device nameplate (
7).
3.
Open the configuration program.
4.
Load the device description file or CFF file into the host system or into the configuration
program. Ensure you use the correct system files. Refer to the example on
43.
The first time it is connected the measuring device reports as follows:
– EH_PROSONIC_FLOW_93_ xxxxxxxxxxx (Tag name PD-TAG)
– 452B481059- xxxxxxxxxxx (Device_ID)
– Block structure:
452B48 1059- XXXXXXXXXXX
Device serial number (11-digit)
Device type (Prosonic Flow 93C)
Hauser
Display text (xxx... = serial number)
Base index
Description
RESOURCE_ xxxxxxxxxxx
400
Resource Block
TRANSDUCER_FLOW_xxxxxxxxxxx
2600
"Flow" Transducer Block
TRANSDUCER_DIAG_xxxxxxxxxxx
1600
"Diagnosis" Transducer Block
TRANSDUCER_SERV_xxxxxxxxxxx
1700
Transducer Block "Service"
TRANSDUCER_DISP_xxxxxxxxxxx
1800
"Display" Transducer Block
TRANSDUCER_TOT_xxxxxxxxxxx
1900
"Totalizer" Transducer Block
ANALOG_INPUT_1_ xxxxxxxxxxx
500
Analog Input function block 1
ANALOG_INPUT_2_ xxxxxxxxxxx
550
Analog Input function block 2
ANALOG_INPUT_3_ xxxxxxxxxxx
600
Analog Input function block 3
ANALOG_INPUT_4_ xxxxxxxxxxx
650
Analog Input function block 4
ANALOG_INPUT_5_ xxxxxxxxxxx
700
Analog Input function block 5
ANALOG_INPUT_6_ xxxxxxxxxxx
750
Analog Input function block 6
ANALOG_INPUT_7_ xxxxxxxxxxx
800
Analog Input function block 7
ANALOG_INPUT_8_ xxxxxxxxxxx
850
Analog Input function block 8
DISCRETE_OUTPUT_ xxxxxxxxxxx
900
Discrete Output Function Block (DO)
PID_ xxxxxxxxxxx
1000
PID Function Block (PID)
ARITHMETIC_xxxxxxxxxxx
1100
Arithmetic Function Block (ARTH)