Installation
Proline Prosonic Flow 93C FOUNDATION Fieldbus
18
Hauser
3.2.10
Length of connecting cable
Shielded cables are available in the following lengths:
5 m (16.4 ft), 10 m (32.8 ft), 15 m (49.2 ft) and 30 m (98.4 ft)
"
Caution!
Route the cables well clear of electrical machines and switching elements.
Flow characteristics of Prosonic Flow C (US units)
Nominal diameter
Recommended flow rate
Factory setting
[inch]
[mm]
Min./max. full scale value
(v ~ 0.3 or 10 m/s)
Creepage
(v ~ 0.04 m/s)
12"
300
350…11900 gal/min
45 gal/min
14"
350
440…14500 gal/min
65 gal/min
16"
400
570…19400 gal/min
90 gal/min
18"
450
700…24700 gal/min
90 gal/min
20"
500
880…30400 gal/min
130 gal/min
24"
600
1320…43600 gal/min
175 gal/min
28"
700
1800…59900 gal/min
240 gal/min
30"
–
2070…70000 gal/min
275 gal/min
32"
800
2380…78800 gal/min
325 gal/min
36"
900
2990…99000 gal/min
400 gal/min
40"
1000
3740…110000 gal/min
500 gal/min
42"
–
4180…118900 gal/min
550 gal/min
48"
1200
5500…132100 gal/min
700 gal/min
54"
–
9.8…203 Mgal/d
1.3 Mgal/d
–
14000
10.5…222 Mgal/d
1.4 Mgal/d
60"
–
12.4…235 Mgal/d
1.6 Mgal/d
–
1600
13.9…254 Mgal/d
1.8 Mgal/d
66"
–
14.6…254 Mgal/d
1.9 Mgal/d
72"
1800
17.7…285 Mgal/d
2.3 Mgal/d
78"
2000
21.6…317 Mgal/d
2.9 Mgal/d
Содержание Proline Prosonic Flow 93C
Страница 2: ......
Страница 90: ...www endress com worldwide BA00145D 06 EN 13 10 71121226 FM SGML6 0 ProMoDo...