14.6. CNT 516
The CNT 516 is a coupling network for coupling surge pulses to 16 lines via a 25
resistor. Depends from where
the pulse is adapted different waveshapes can be applied to the EUT.
14.6.1. Operating elements
1
HV Output T1...T16
2
COM output
3
Earth bolt
4
COM input
5
HV input
14.6.2. Technical data:
As per IEC 61000-4-5 and other relevant standards
Pulse 10/700
s or 1.2/50
s
Open circuit voltage
160V
– 7,000V
10%
Serial resistor per output
25
±10%
Number of parallel HV outputs
16
Number of COM outputs
3
Coupling
Channels
16 channels in parallel T1 to T16 with 25
each
Dimensions
Housing
19“, 3HU, 448x250x143mm
Weight
6.25kg