EM TEST
UCS 500 Series
Operating Manual
V 5.40
53 / 99
F4
IEC coupling after n pulses
The coupling mode will automatically be changed after the
preselected number of pulses has been released. All
possible coupling modes will be selected. . The same
parameters as under Quick Start can be selected.
F5
ANSI A coupling after n pulses
The coupling mode with 12
Ω und 9µF will automatically be
changed after the preselected number of pulses has been
released. All possible coupling modes will be selected. . The
same parameters as under Quick Start can be selected.
F6
ANSI B coupling after n pulses
The coupling mode with 2
Ω und 18µF will automatically be
changed after the preselected number of pulses has been
released. All possible coupling modes will be selected. . The
same parameters as under Quick Start can be selected.
Surge Generator and coupling impedances
Line to Line
Line to PE
(IEC)
Line to GND
(ANSI
)
IEC
2
Ω; 18µF
12
Ω; 9µF
ANSI A
12
Ω; 9µF
12
Ω; 9µF
ANSI B
2
Ω; 18µF
2
Ω; 18µF