EM TEST
UCS 500 Series
Operating Manual
V 5.40
32 / 99
6.9.2.
UCS 500N5.5 and UCS 500N5.6 and UCS 500N5.9 for Railways application
Standards:
-
EN 50121-3-2: 2015
-
EN 50121-4: 2015
-
EN 50121-5: 2015
Module
:
Burst
Surge
EUT
UCS 500N5.5:
300V 32A
UCS 500N5.6:
300V 32A
UCS 500N5.9:
300V 16A
Module
Built in modules
UCS 500N5.5:
Burst, Surge
UCS 500N5.6:
Burst, Surge, Power Fail
UCS 500N5.9:
Burst, Surge, Power Fail
Surge Coupling
L - N,
L - PE,
N - PE,
L + N - PE
Surge impedance Ri
2
, 10
, 40
Must be set manually by a bridge
R
EMARK
:
The complete Ri impedance is the addition of the 2
generator impedance und the manually set impedance
(10
, 40
).
Coupling\ Ri
2
12
42
/ 0.5 µF
L - N
ok
ok
ok
L - PE
N - PE
no pulse
ok
ok
L + N - PE
no pulse
ok
ok
Dimensions and weight
Dimension
450 x 550 x 285 mm
Weight
34.2kg
Housing
6HU