Emerson Process Management GmbH & Co. OHG
9-46
X-STREAM XE
Instruction Manual
HASXEE-IM-HS
10/2012
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address
Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
8018
5035…
5036
Service.Status.NAMUR.FctCheck-
Map
DWord
R/W
Bitmask that maps cond. for FctCheck source
8021
5041…
5042
Status.NamurStates.FailAlarmDev
DWord
RO
NamurFailure alarms that are device related
8022
5043…
5044
Status.NamurStates.OffSpecAlarm
-
Dev
DWord
RO
NamurOff-spec alarms that are device related
8023
5045…
5046
Status.NamurStates.MaintRequAl-
armDev
DWord
RO
NamurMaintRequ alarms that are device related
8024
5047…
5048
Status.NamurStates.FctCheckAlar-
mDev
DWord
RO
Namur FctCheck alarms that are device related
8025
5049…
5050
Status.NamurStates.FailAlarm-
Comp1
DWord
RO
NamurFailure alarms that are component1 related
8026
5051…
5052
Status.NamurStates.OffSpecAlarm
-
Comp1
DWord
RO
Namur Off-spec alarms that are component1
related
8027
5053…
5054
Status.NamurStates.MaintRequAl-
armComp1
DWord
RO
Namur MaintRequ alarms that are component1
related
8028
5055…
5056
Status.NamurStates.FctCheckA-
larmComp1
DWord
RO
Namur FctCheck alarms that are component1
related
8029
5057…
5058
Status.NamurStates.FailAlarm-
Comp2
DWord
RO
NamurFailure alarms that are component2 related
8030
5059…
5060
Status.NamurStates.OffSpecAlarm
-
Comp2
DWord
RO
Namur Off-spec alarms that are component2
related
8031
5061…
5062
Status.NamurStates.MaintRequAl-
armComp2
DWord
RO
Namur MaintRequ alarms that are component2
related
8032
5063…
5064
Status.NamurStates.FctCheckA-
larmComp2
DWord
RO
Namur FctCheck alarms that are component1
related
8033
5065…
5066
Status.NamurStates.FailAlarm-
Comp3
DWord
RO
NamurFailure alarms that are component3 related
8034
5067…
5068
Status.NamurStates.OffSpecAlarm
-
Comp3
DWord
RO
Namur Off-spec alarms that are component3
related
8035
5069…
5070
Status.NamurStates.MaintRequAl-
armComp3
DWord
RO
Namur MaintRequ alarms that are component3
related
8036
5071…
5072
Status.NamurStates.FctCheckA-
larmComp3
DWord
RO
Namur FctCheck alarms that are component1
related
8037
5073…
5074
Status.NamurStates.FailAlarm-
Comp4
DWord
RO
NamurFailure alarms that are component4 related
8038
5075…
5076
Status.NamurStates.OffSpecAlarm
-
Comp4
DWord
RO
Namur Off-spec alarms that are component4
related
8039
5077…
5078
Status.NamurStates.MaintRequAl-
armComp4
DWord
RO
Namur MaintRequ alarms that are component4
related
8040
5079…
5080
Status.NamurStates.FctCheckA-
larmComp4
DWord
RO
Namur FctCheck alarms that are component1
related
8041
5081…
5082
Status.NamurStates.FailAlarm-
Comp5
DWord
RO
NamurFailure alarms that are component5 related
8042
5083…
5084
Status.NamurStates.OffSpecAlarm
-
Comp5
DWord
RO
Namur Off-spec alarms that are component5
related
Содержание Rosemount X-Stream Series
Страница 370: ...Emerson Process Management GmbH Co OHG 7 82 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...
Страница 414: ...Emerson Process Management GmbH Co OHG 8 44 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...
Страница 486: ...Emerson Process Management GmbH Co OHG A 4 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 488: ...Emerson Process Management GmbH Co OHG A 6 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 490: ...Emerson Process Management GmbH Co OHG A 8 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 526: ...Emerson Process Management GmbH Co OHG A 44 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...