Modbus Commands
9.4 List of Parameters and Registers - Sorted by Daniel Registers
Address
Tag Name
Data
Type
Client
Access
Description
Daniel Modicon
3310
3310
Setup.Calibration.SpanMethod5
Word
R/W
span cal method comp5 (0=Instant, 1=Stability)
3311
3311
Service.Calibration.ChanProc
-
Mode1
Word
R/W
cal proc mode comp1 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3312
3312
Service.Calibration.ChanProc
-
Mode2
Word
R/W
cal proc mode comp2 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3313
3313
Service.Calibration.ChanProc
-
Mode3
Word
R/W
cal proc mode comp3 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3314
3314
Service.Calibration.ChanProc
-
Mode4
Word
R/W
cal proc mode comp4 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3315
3315
Service.Calibration.ChanProc
-
Mode5
Word
R/W
cal proc mode comp5 (0=Disabled 1=Manual
2=SingleAuto 3=AdvCal)
3316
3316
Service.Calibration.Tubing
Word
R/W
Tubing (0=Parallel 1=Serial)
3397
3397
Setup.Communication.SIntMod-
busFt32
Word
R/W
Modbus 32Bit mode of serial COM
3398
3398
Setup.Communication.SSvcMod-
busFt32
Word
R/W
Modbus 32Bit mode of serial service COM
3399
3399
Setup.Communication.Eth2Mod-
busFt32
Word
R/W
Modbus 32Bit mode of Ethernet2
3400
3400
Setup.Communication.Eth1Mod-
busFt32
Word
R/W
Modbus 32Bit mode of Ethernet1
3401
3401
Service.Measurement.Compensa-
tion.ToffEnable1
Word
R/W
enable temperature zero compensation of comp1
3402
3402
Service.Measurement.Compensa-
tion.ToffEnable2
Word
R/W
enable temperature zero compensation of comp2
3403
3403
Service.Measurement.Compensa-
tion.ToffEnable3
Word
R/W
enable temperature zero compensation of comp3
3404
3404
Service.Measurement.Compensa-
tion.ToffEnable4
Word
R/W
enable temperature zero compensation of comp4
3405
3405
Service.Measurement.Compensa-
tion.ToffEnable5
Word
R/W
enable temperature zero compensation of comp5
3406
3406
Service.Measurement.Compensa-
tion.ToffSensorAssign1
Word
R/W
assign temp-sensor of zero comp1 (0=None
1=DSP_T1 2=DSP_T2 etc.
3407
3407
Service.Measurement.Compensa-
tion.ToffSensorAssign2
Word
R/W
assign temp-sensor of zero comp2 (0=None
1=DSP_T1 2=DSP_T2 etc.
3408
3408
Service.Measurement.Compensa-
tion.ToffSensorAssign3
Word
R/W
assign temp-sensor of zero comp3 (0=None
1=DSP_T1 2=DSP_T2 etc.
3409
3409
Service.Measurement.Compensa-
tion.ToffSensorAssign4
Word
R/W
assign temp-sensor of zero comp4 (0=None
1=DSP_T1 2=DSP_T2 etc.
3410
3410
Service.Measurement.Compensa-
tion.ToffSensorAssign5
Word
R/W
assign temp-sensor of zero comp5 (0=None
1=DSP_T1 2=DSP_T2 etc.
3411
3411
Service.Measurement.Compensa-
tion.TfactEnable1
Word
R/W
enable temperature span compensation of comp1
3412
3412
Service.Measurement.Compensa-
tion.TfactEnable2
Word
R/W
enable temperature span compensation of comp2
3413
3413
Service.Measurement.Compensa-
tion.TfactEnable3
Word
R/W
enable temperature span compensation of comp3
Содержание Rosemount X-Stream Series
Страница 370: ...Emerson Process Management GmbH Co OHG 7 82 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...
Страница 414: ...Emerson Process Management GmbH Co OHG 8 44 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...
Страница 486: ...Emerson Process Management GmbH Co OHG A 4 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 488: ...Emerson Process Management GmbH Co OHG A 6 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 490: ...Emerson Process Management GmbH Co OHG A 8 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 A 1 Modbus Specification ...
Страница 526: ...Emerson Process Management GmbH Co OHG A 44 X STREAM XE Instruction Manual HASXEE IM HS 10 2012 ...
Страница 535: ......