September 2006, version 5.x
Modification type
Change
Expansion
•
Discrete Output assignable as a flow switch
•
Discrete Output fault indication configurability
•
Discrete Input support for multiple action assignments
•
Added support for querying the display LED status via Mod-
bus
•
Additional HART and Modbus commands
•
Process comparator expanded to five configurable events
•
Factory configuration restore function
•
Factory zero restore function
•
Alarm history expanded
•
Selectable write protection for configuration data
•
Expanded selection of source assignments for mA Output
•
Expanded storage of mA range values
•
Expanded custody transfer application for independent im-
plementation of NTEP and OIML compliance
Adjustment
Display improvements for floating-point data
Feature
•
Configurable alarm severity
•
Gas standard volume functionality
•
Meter verification availability as an option
•
Multiple display language selections
September 2009, version 6.x
Modification type
Change
Expansion
•
Frequency Output configurable as Discrete Output on Series
1000 transmitters
•
Discrete Output assignable as flow switch on Series 1000
transmitters
•
Display Variable 1 optionally fixed to process variable as-
signed to primary mA Output
•
Frequency Output scaling method and related parameters
configurable from display
•
For enhanced density and petroeum measurement process
variables, display cycles among variable name, current value
and unit, and reference temperature
Adjustment
•
mA Output Fault Action = None and Digital Communications
Fault Action = NAN is no longer allowed
•
Frequency Output Fault Action = None and Digital Communi-
cations Fault Action = NAN is no longer allowed
•
Display variables set to a volume process variable automati-
cally switch between liquid and GSV, according to current
setting of Volume Flow Type
NE 53 history
Configuration and Use Manual
225
Содержание Micro Motion 2500
Страница 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 20: ...Configuration and commissioning 12 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 124: ...Complete the configuration 116 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 130: ...Set up the Weights Measures application 122 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 132: ...Operations maintenance and troubleshooting 124 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 140: ...Transmitter operation 132 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 216: ...Using ProLink III with the transmitter 208 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 226: ...Default values and ranges 218 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 237: ...NE 53 history Configuration and Use Manual 229 ...