Derived
Variable
Description
Calculated process variables
Density at
reference
tempera-
ture
Standard
volume
flow rate
Specific
gravity
Concen-
tration
Net mass
flow rate
Net
volume
flow rate
Density
at Reference
Mass/unit volume, cor-
rected to a given refer-
ence temperature
✓
✓
Specific Gravity
The ratio of the density
of a process fluid at a
given temperature to
the density of water at
a given temperature.
The two given temper-
ature conditions do not
need to be the same.
✓
✓
✓
Mass
Concentration
(Density)
The percent mass of
solute or of material in
suspension in the total
solution, derived from
reference density
✓
✓
✓
✓
Mass
Concentration
(Specific Gravity)
The percent mass of
solute or of material in
suspension in the total
solution, derived from
specific gravity
✓
✓
✓
✓
✓
Volume
Concentration
(Density)
The percent volume of
solute or of material in
suspension in the total
solution, derived from
reference density
✓
✓
✓
✓
Volume
Concentration
(Specific Gravity)
The percent volume of
solute or of material in
suspension in the total
solution, derived from
specific gravity
✓
✓
✓
✓
✓
Concentration
(Density)
The mass, volume,
weight, or number of
moles of solute or of
material in suspension
in proportion to the to-
tal solution, derived
from reference density
✓
✓
✓
Configure process measurement
Configuration and Use Manual
57
Содержание Micro Motion 2500
Страница 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 20: ...Configuration and commissioning 12 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 124: ...Complete the configuration 116 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 130: ...Set up the Weights Measures application 122 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 132: ...Operations maintenance and troubleshooting 124 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 140: ...Transmitter operation 132 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 216: ...Using ProLink III with the transmitter 208 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 226: ...Default values and ranges 218 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 237: ...NE 53 history Configuration and Use Manual 229 ...