Tip
If the standard matrices are not appropriate for your application, you can build a custom matrix or
purchase a custom matrix from Micro Motion.
Matrix name
Description
Density unit
Temperature
unit
Derived variable
Deg Balling
Matrix represents percent extract, by
mass, in solution, based on °Balling.
For example, if a wort is 10 °Balling
and the extract in solution is 100% su-
crose, the extract is 10% of the total
mass.
g/cm
3
°F
Mass Concentration
(Density)
Deg Brix
Matrix represents a hydrometer scale
for sucrose solutions that indicates the
percent by mass of sucrose in solution
at a given temperature. For example,
40 kg of sucrose mixed with 60 kg of
water results in a 40 °Brix solution.
g/cm
3
°C
Mass Concentration
(Density)
Deg Plato
Matrix represents percent extract, by
mass, in solution, based on °Plato. For
example, if a wort is 10 °Plato and the
extract in solution is 100% sucrose, the
extract is 10% of the total mass.
g/cm
3
°F
Mass Concentration
(Density)
HFCS 42
Matrix represents a hydrometer scale
for HFCS 42 (high-fructose corn syrup)
solutions that indicates the percent by
mass of HFCS in solution.
g/cm
3
°C
Mass Concentration
(Density)
HFCS 55
Matrix represents a hydrometer scale
for HFCS 55 (high-fructose corn syrup)
solutions that indicates the percent by
mass of HFCS in solution.
g/cm
3
°C
Mass Concentration
(Density)
HFCS 90
Matrix represents a hydrometer scale
for HFCS 90 (high-fructose corn syrup)
solutions that indicates the percent by
mass of HFCS in solution.
g/cm
3
°C
Mass Concentration
(Density)
4.8.4
Derived variables and calculated process variables
The concentration measurement application calculates a different set of process variables
from each derived variable. The process variables are then available for viewing or
reporting.
Configure process measurement
56
Micro Motion Model 2500 Transmitters with Configurable Input/Outputs
Содержание Micro Motion 2500
Страница 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 20: ...Configuration and commissioning 12 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 124: ...Complete the configuration 116 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 130: ...Set up the Weights Measures application 122 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 132: ...Operations maintenance and troubleshooting 124 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 140: ...Transmitter operation 132 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 216: ...Using ProLink III with the transmitter 208 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 226: ...Default values and ranges 218 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 237: ...NE 53 history Configuration and Use Manual 229 ...