10.2
Switch between secured and unsecured mode
You must switch to unsecured mode to change the transmitter configuration or perform
many administrative tasks. You must switch back to secured mode in order to meet
Weights & Measures requirements for process measurement.
You must use one of the following tools to switch modes:
•
ProLink III
•
The Custody Transfer switching utility. The switching utility is free, and is available
from the Software Downloads page at
.
The controls are not accessible in any other way.
10.2.1
Switch between secured and unsecured mode using
ProLink III
Prerequisites
Before switching to unsecured mode, ensure that you will be able to switch back to
secured mode. Because switching to unsecured mode requires breaking the physical seal,
switching back to secured mode may require a site visit from a certified Weights &
Measures inspector and reinstallation of the physical seal.
Ensure that the wiring is in place for a service port connection. You may need to break the
seal and remove the clamp.
Ensure that the RS-485 terminals are in service port mode. You may need to power-cycle
the transmitter.
Procedure
•
To switch from secured mode to unsecured mode:
1. Make a service port connection to your transmitter.
2. Choose Device Tools > Configuration > Weights & Measures.
3. Set Software Securityto
Disabled
.
•
To switch from unsecured mode to secured mode:
1. Make a service port connection to your transmitter.
2. Choose Device Tools > Configuration > Weights & Measures.
3. Set Software Securityto
Enabled
.
10.2.2
Switch between secured and unsecured mode using the
switching utility
Prerequisites
The switching utility must be installed on your PC. The switching utility is available from
the Software Downloads page at
.
Operate the transmitter with the Weights & Measures application
138
Micro Motion Model 2500 Transmitters with Configurable Input/Outputs
Содержание Micro Motion 2500
Страница 8: ...Contents vi Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 10: ...Getting started 2 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 18: ...Quick start 10 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 20: ...Configuration and commissioning 12 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 124: ...Complete the configuration 116 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 130: ...Set up the Weights Measures application 122 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 132: ...Operations maintenance and troubleshooting 124 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 140: ...Transmitter operation 132 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 216: ...Using ProLink III with the transmitter 208 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 226: ...Default values and ranges 218 Micro Motion Model 2500 Transmitters with Configurable Input Outputs ...
Страница 237: ...NE 53 history Configuration and Use Manual 229 ...