EK280
Application Manual
151
9.8
Calibration data log
With the aid of the calibration data log, several parameters which are relevant from a statutory calibration
viewpoint (see the EK280 operating instructions) can be changed when the administrator lock is open.
A data row is entered for each alteration of such a parameter when the calibration lock is closed. In addition,
an entry is always made when opening and closing the calibration lock.
i
The calibration data log is not a flexible archive.
9.8.1
Deactivating the calibration data log
In order to deactivate the calibration data log on the device, open the calibration lock as described in
the EK280 operating instructions.
Move the cursor to
"Serv."
>
"Archives" > "CDL".
Press the ENTER button
"on"
flashes.
Change the value using the arrow buttons
or
to
"off"
.
Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the
ESC button.
i
If the calibration data log is deactivated then the values affected are locked in a calibration lock.
9.8.2
Archive content
Pos.
Address
Display
Description
Retrievable
1
01:01F8 GONo
Global Block number
S
2
09:0A20 ABNo
Archive Block number
A + S
3
01:0400 Time
Date and time
A + S
4
09:0810 Add
Address
A + S
5
09:0811 old
old value
A + S
6
09:0812 new
new value
A + S
7
01:0170 St.PL
Status of calibration lock
A + S
8
02:0170 St.ML
Status of manufacturer lock
A + S
9
03:0170 St.AL
Status of administrator lock
A + S
10
04:0170 St.CL
Status of customer lock
A + S
11
05:0170 St.DL
Status of data collectors lock
A + S
12
06:0170 StU6L
Status lock 6
A + S
13
07:0170 StUpL
Status of software update lock
A + S
14
08:0170 StCDL
Status of CDL lock
A + S
15
01:070C UsOpt
Active Interface: Optical interface
A + S
16
02:070C UsTrm
Active Interface: Terminal interface
A + S
17
03:070C UsMod
Active Interface: Internal modem
A + S
18
09:0A21 Check
Check sum result ( „CRC OK“ or „Error“)
A + S
9.8.3
Memory capacity
The calibration data log contains 50 data rows.
As the first data row always logs the closing of the calibration lock, and the last row is always kept free for
the opening of the calibration lock then a maximum of 48 parameter changes can be entered.
Содержание EK280
Страница 1: ...EK280 Application Manual Issue 2016 1 Software Version 2 31 et seq ...
Страница 2: ......