EK280
Application Manual
21
b)
Archiving of original counter value of the gas counter "
Vo
":
So that "
Vo
" (meter reading of the gas meter) is stored in the measurement period archive, daily archive and
monthly archive 1 instead of "
VmG
" (total operating volume), then use the "enSuite" parameterization
program to send the following parameter file to the EK280 (see chapter 3.6 "Send parameter file", page 17):
i
After loading the WPP file, the measurement period archive, the daily archive and monthly
archives 1 and 2 are deleted!
EK280 - Archive1,3,7 Vo in Archive (ATTENTION Archives will be deleted!) (*)
1
c)
Archiving the operating volume, total ("
VmG
") (factory preset):
So that "
VmG
" (total operating volume) is stored in the measurement period archive, daily archive and
monthly archive 1 again (default setting) instead of "
Vo
" (meter reading of the gas meter), then use the
"enSuite" parameterization software to send the following parameter file to the EK280 (see chapter 3.6
"Send parameter file", page 17):
i
After adding the WPP file, the measurement period archive, the daily archive and monthly
archives 1 and 2 are deleted!
EK280 - Archive1,3,7 VbG in Archive (ATTENTION Archives will be deleted!) (*)
1
The star * designates the file version, e.g., "a"