
EK280
Application Manual
145
9.3.4
Values relating to months
9.3.4.1 In the current month
To display the volumes relating to the monthly limit, move the cursor to
"Serv."
>
"Volume" > "current month".
Display
Description
VbMPc
Maximum VbMP of current month
VbDyc
Maximum VbDy of current month
VbMoc
Vb Monthly interval meter progress of the current month
VmMPc
Maximum VmMP of current month
VmDyc
Maximum VmDy of current month
VmMoc
Vm Monthly interval meter progress of the current month
W.MPc
33
Maximum W.MP of current month
W.Dyc
Maximum W.Dy of current month
The counter progress compared to the respective previous entry is denoted with a "
". Normally it is a flow
(consumption) in this case within a day. This, however, does not apply when an archive row is entered due to
a particular event (e.g. setting the clock or a counter, appearance of an important status message). The meter
reading flashes with the meter progress to point out this feature to the user (for further information, refer to the
instruction manual "usage as a registration device").
9.3.4.2 In the previous month
To display the volumes relating to the monthly limit, move the cursor to
"Serv."
>
"Volume" > "previous
month".
Display
Description
VbMP
Maximum VbMP of last month
VbDy
Maximum VbDy of last month
VbMo
Vb Monthly interval meter progress of the previous month
VmMP
Maximum VmMP of last month
VmDy
Maximum VmDy of last month
VmMo
Vm Monthly interval meter progress of the previous month
W.MP
Maximum W.MP of last month
W.Dy
Maximum W.Dy of last month
The counter progress compared to the respective previous entry is denoted with a "
". Normally it is a flow
(consumption) in this case within a day. This, however, does not apply when an archive row is entered due to
a particular event (e.g. setting the clock or a counter, appearance of an important status message). The meter
reading flashes with the meter progress to point out this feature to the user (for further information, refer to the
instruction manual "usage as a registration device").
9.3.5
Delete monthly archive 1
See Chapter 2.4.2 Clear volumes and archives ("Clr.V") or 2.4.3 Clear archives ("Clr.A").
33
This value is only displayed when the
“
Menu option 1: With energy
” is set. Use enSuite
Parameters > Device
settings > Display > Menu options
.
Содержание EK280
Страница 1: ...EK280 Application Manual Issue 2016 1 Software Version 2 31 et seq ...
Страница 2: ......