EK280
Application Manual
141
Move the cursor to
"Serv."
>
"Archives" > "FrMP".
Press the ENTER button
"0"
flashes.
Change the value using the arrow buttons
or
to
"1"
.
Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the
ESC button.
On the basis of the event "Ev" stored as a triggering event the data row indicates whether it was stored
automatically due to the elapsed measurement period or by triggering the
"FrMP"
.
9.1.7
Delete measurement period archive
See Chapter 2.4.2 Clear volumes and archives ("Clr.V") or 2.4.3 Clear archives ("Clr.A").
9.2
Daily archive
In the daily archive meter readings and measured values are archived in regular daily period
"DayB"
.
The content of the daily archive can be shown on the display of the device via the path
"Serv." > "Archives" >
"Daily Archive"
.
i
The daily archive period archive is a flexible archive.
Archive contents and the memory capacity can be adapted with corresponding settings via
"enSuite" parameterization software when the administrator lock is open.
Our applications team is available if you require further information.
9.2.1
Archive content
Pos. Address
Display
Description
Retrievable
1
01:01F8 GONo
Global Block number
S
2
07:0A20 ABNo
Archive Block number
A + S
3
01:0400 Time
Date and time
A + S
4
02:0300 Vb
Volume at base conditions
A + S
5
-
Vb
Meter progress Volume at base conditions
A
6
02:0302 VbT
Volume at base conditions total
A + S
7
-
VbT
Meter progress Volume at base conditions total
A
8
04:0300 Vm
Volume at measurement conditions
A + S
9
-
Vm
Meter progress Volume at measurement conditions
A
10
04:0302 VmT
Volume at measurement conditions total
2
A + S
11
-
VmT
Meter progress Volume at measurement cond. total
A
12
35:0161 p.MP
Pressure mean value of last meas period
A + S
13
34:0161 T.MP
Daily mean temperature value
A + S
14
36:0161 K.MP
Mean value K of last meas period
A + S
15
37:0161 C.MP
Mean value C of last meas period
A + S
16
02:0110 St.2
Instance-Status 2 (incl. Vn)
A + S
17
04:0110 St.4
Instance -Status 4 (incl. Vb)
A + S
18
07:0110 St.7
Instance -Status 7 (incl. p)
A + S
19
06:0110 St.6
Instance -Status 6 (incl. T)
A + S
20
02:0100 StSy
System-Status
A + S
21
03:0A23 ErReg
Error register
A
22
07:0A22 Ev
Event causing data line to be archived
A + S
23
07:0A21 Check
Check sum result ( „CRC OK“ or „Error“)
A + S
The values can be retrieved in accordance with the information in the table via D = display and/or
I = interface.
When using an encoder then the original operating volume "Vo" (01 240) can also be set.