52
Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Select Yes to activate the heat recovery function (with No, the function is switched off).
Use the arrow keys that appear to set the indoor temperature beneath which circula-
tion should take place, and the level at which the ventilator should run.
Default setting: Indoor temperature 10.0°C lower; with level 3.
Confirm your setting with the
OK
button.
Press the button to set the recirculating air function for condensation reduction. Recir-
culation of the air can reduce condensation forming on the window panes.
Select
Yes
to activate the condensation reduction function (with No, the function is
switched off). Using the arrow keys that appear, set the U-value of the glass used (ask
your window manufacturer or conservatory supplier for the value) and the level at
which the ventilator should run. Default setting: U-value 1.0; with Level 3.
Confirm your setting with the
OK
button.
Press the button to set the indoor temperature above which the circulating air heating
will be switched on during the day. Until an indoor sensor is selected, the automatic
heating is deactivated. Use the arrow buttons to change the value according to your
wish. Default setting: 16.0 °C.
Confirm your setting with the
OK
button.
Press the button to set the night-time operation for the circulating air heating. Press
Select
to select the time during which the night mode will operate. Activate one or
more periods on the list. The periods can be individually customised (see below).
Confirm your setting with the
OK
button.
To change any of the time periods, press
Timer
.
3.3. Set timer
Press the button to set the indoor temperature above which the heating will be
switched on at night. The button is only active if a night mode operation period has
been set. Use the arrow buttons to change the value according to your wish. Default
setting: 9.0°C
Confirm your setting with the
OK
button.
Condensation
Only for roof ventilators WL610 and WL305.
Temp. Heating
Only for fresh air/heating-combos on RF-VM.
Night mode
Only for fresh air/heating-combos on RF-VM.
Indoor Temp. Night