46
Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
The conditions for the triggering of the frost alarm (outdoor temperature, period) are
defined in the menu „General Settings“.
System > Automatic Settings > General Settings > Frost Alarm
3.3. Adjust frost alarm
When the frost alarm is triggered, manual operation of the window is initially blocked.
You can remove the block manually however. To do this select the appropriate window
in the Manual menu and press the frost alarm button. If the button is shown normally
(black writing), the block has been removed. The block will then be first active for this
drive again when it is reactivated manually or the next time the frost alarm is triggered.
Activate: If the window is to be closed when there is a frost alarm, select
Yes
.
Deactivate: If ventilation is to take place via the window regardless of the frost risk, se-
lect
No
(default setting).
Confirm your setting with the
OK
button.
Press the button to set the wind alarm. The wind alarm protects the unit and equipment
from damage by closing the window. The wind alarm will also close manually opened
windows.
Adjust values: Use the arrow keys to adjust the value for wind speed and the length of
time by which it must have been exceeded.
Disable: If the window should not react to the wind, select
Never close
(default set-
ting).
Confirm your setting with the
OK
button.
A wind alarm triggered for the drive will be maintained for 5 minutes. If during these 5
minutes the saved value is exceeded again, the holding time begins again.
Press the button to enable or disable the rain alarm. The rain alarm protects against
moisture damage by closing the window. The rain alarm will also close manually
opened windows.
Enable: If the window should be closed when there is rain, select
Yes.
Disable: If the window should remain open when there is rain, select
No
(default set-
ting).
Confirm your setting with the
OK
button.
Wind Alarm