134
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
7.3.
Alarm and error messages
7.3.1. Weather data display messages
Various alarm and error messages can appear in the weather data display. In this case
no weather animation will be shown.
Alarm from motion detector
is shown when a connected motion sensor has been activated. When there is a motion-
detector alarm, windows close automatically; if applicable, the light is switched on. Af-
ter 5 minutes without another signal from the motion detector, the warning disappears
and the control system returns the windows to normal automatic mode.
Fire alarm! By “XX” (sensor name)
is shown if the control system receives a signal from a smoke detector. At the same
time awnings and blinds retract, the light comes on, heatings and air conditioners
switch off, windows and ventilators open/switch on. Manual operation is blocked. A
warning system sounds at the control system. The fire alarm can only be switched off
by a Reset/Restart of the control system through the
System > WS1 / WS1000 Set-
tings > Service > Reset
menu or by cutting off the power supply.
Please set clock!
is shown when the control system is first started or after a restart. As soon as a time
signal is received, this message disappears. If no reception is available, please set the
clock by hand.
System > WS1 / WS1000 settings > Settings > Time and Date
6.2. Enter time and date manually
Connection to weather station failed!
means that the control system is receiving no data from the weather station. Check the
connection lead to the weather station and examine it if necessary.
Manual
operation
of drives and devices without rain or wind alarm is still possible. Drives with selected
rain or wind alarm move to the safe position.
RF868 wireless module faulty!
means that the internal wireless module is not working properly. Contact customer ser-
vice to have the control unit checked.