61
Eaton RF-System
© 2015 Eaton Electrical Group
Basic Mode). Some functions occupy more than just one command button, as we will see in the
following function descriptions:
Among them, depending on the functions that are set, several slider controls (control time,
runtime, interval time), which allow you set time-related functions.
Another item is setting the dimming time, which defines how long it takes a dimmer to dim from 0%
to 100%. It can be selected individually for each command, but the maximum dimming time is 250
seconds.
5. In this box (bottom right) you can set the dimming limits as well as the behaviour of the
transmitter in case of power recovery or low battery.
The dimming limits define the range within which the actuator will dim (standard min. 20% to max.
100%).
In case the sensor battery is low, you can select whether or not the dimming actuator should send
a warning after switching it on (output blinks once).
Regarding power recovery, you can pre-set how the dimming actuator should react to it. There are
three options to choose from:
Old value (Standard): Actuator maintains the same state as before the power
failure
On: After power recovery the actuator switches the output ON
Off: After power recovery the actuator switches the output OFF
6. By setting this option, the dimming actuator remembers the last value used before switching off
and switches on again to precisely this value when it receives the next ON command.
All functions of the dimming actuator:
On / Off Dimming (Standard), occupies 4 command buttons
Switches ON presp. OFF
On / Switch-on Delay, occupies 1 command button
ON command that comes either immediately or after an adjustable delay time
Off / On with Switch-off Delay, occupies 1 command button
OFF command that comes either immediately or after an adjustable delay time
On and Off with Advance Warning, occupies 1 command button
Stair case function which switches on immediately and turns off after an adjustable time.
Before
the dimming actuator switches off, the output will blink once 15 seconds earlier as an
advance warning.
Key-Dim-Mode, occupies 2 command buttons
The dimmer switches ON after a short push at the push-button or key, and OFF after a
long push at the push-button or key, and it dims up or down after a long push at the
push-button or key.
Surge, occupies 1 command button
The dimming actuator changes its initial state by dimming each time it is activated.
Blinking, occupies 1 command button, takes the dimming time into account
After activating it, the dimming actuator starts blinking after an adjustable interval time
Desired Brightness, occupies 1 command button
The dimming actuator dims to a pre-set brightness value, at the pre-set dimming speed
(dimming time)
Dim brighter occupies one command box (long press of the button)
Dims brighter as long as the button is held depending on the dimming limits and the
dimming time
Dim darker occupies one command box (long press of the button)
Dims darker as long as the button is held depending on the dimming limits and the
dimming time
No Function, occupies 1 command button
No function
–
as its name implies
Functions for buttons, hand-held transmitter, Home Manager, Room Manager and Bin Bat/230
Mode4:
Содержание RF System 2.42
Страница 1: ...Eaton RF System 2 42 Manual...
Страница 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Страница 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Страница 197: ...197 Eaton RF System 2015 Eaton Electrical Group 4 Now we select the desired function e g On switch on delay...
Страница 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Страница 218: ...218 Eaton RF System Help 2015 Eaton Electrical Group Step 4 Configuration of device type dimming actuator...
Страница 219: ...219 Eaton RF System 2015 Eaton Electrical Group Step 5 Configuration of device type analogue actuator...
Страница 220: ...220 Eaton RF System Help 2015 Eaton Electrical Group Step 6 Configuration of device type shutter actuator...
Страница 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Страница 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Страница 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Страница 226: ...226 Eaton RF System Help 2015 Eaton Electrical Group Group settings binary input 230V Group settings Motion detector...
Страница 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...
Страница 229: ...229 Eaton RF System 2015 Eaton Electrical Group Group settings Analogue input Group settings Impulse input...