239
Eaton RF-System
© 2015 Eaton Electrical Group
If Yes, you will be shown the new password once again. If No, you will be shown the old password
once again. In both cases, you will have the option of redefining the project password.
Password-protected devices were found:
If the current project password does not match the password in the scanned devices, you must
enter the correct password for all "blocked devices". These devices will then also receive the
current project password in MRF (the password will not yet be loaded, however).
With the option "Use as new password for all devices" (under the input field), you can assign the
password that you use to unblock a blocked device, to the entire project (like Define a Password).
This option is normally deactivated. If this option is activated and you now unblock devices with the
correct password, the entire project will be assigned this password.
If you have forgotten the password to one or more devices, you will have the option to reset them
using the Forgot... button, however you must have "On-Site Access" to the devices.
If this involves sensors, you must energise/activate them after pressing Forgot...
–
the basic
settings will be loaded in the device and the password will be deleted.
With power-supplied actuators, you must reset them through the programming button (see Basic
Mode programming plan).
Home Managers and Room Managers can be reset through the Settings menu, and you can set
the communications interface to factory default settings, deleting the password in the process,
through the Homeputer Software by going to the menu items: "Configure -> Hardware interface...
-> Reset interface".
With Cancel, all locked devices are deleted from the screen, and you will only work with unlocked
devices, i.e. with those for which correct passwords have been entered.
Project-Password:
Define password:
You can define a password for the system under this menu item. Each device forming part of the
project, or which is to be scanned at a later date, will receive this password when loading
(password, changes or complete).
Содержание RF System 2.42
Страница 1: ...Eaton RF System 2 42 Manual...
Страница 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Страница 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Страница 197: ...197 Eaton RF System 2015 Eaton Electrical Group 4 Now we select the desired function e g On switch on delay...
Страница 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Страница 218: ...218 Eaton RF System Help 2015 Eaton Electrical Group Step 4 Configuration of device type dimming actuator...
Страница 219: ...219 Eaton RF System 2015 Eaton Electrical Group Step 5 Configuration of device type analogue actuator...
Страница 220: ...220 Eaton RF System Help 2015 Eaton Electrical Group Step 6 Configuration of device type shutter actuator...
Страница 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Страница 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Страница 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Страница 226: ...226 Eaton RF System Help 2015 Eaton Electrical Group Group settings binary input 230V Group settings Motion detector...
Страница 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...
Страница 229: ...229 Eaton RF System 2015 Eaton Electrical Group Group settings Analogue input Group settings Impulse input...