In this configuration the Multi-Heating actuator works in the operation type Heating only therefor we
recommend plugging the jumpers on the Multi-Heating actuator for each channel to „Heating only“.
That will make sure that these channels will never be controlled when operation type cooling is
active.
Operation with Room-Manager:
In this case every connected channel of the Multi-Heating actuator receives Set- and actual
temperature from a Room of the Room-Manager. Each Room can be connected to multiple inputs
of the Multi-Heating actuator but each input can only have one connection.
If an input of the Multi-Heating actuator is used for „Heating only“, „Cooling only“ or „Heating and
Cooling“ can be defined when drawing the connection.
Before connecting Rooms with inputs of the Multi-Heating actuator you have to make sure that the
Room-Manager and Multi-Heating actuator always are in the same operation type. This is done by
connecting the „Operation type output“ of the Room-Manager with the „Heating/Cooling“ input of
the Multi-Heating actuator. .
The Set values and the timer programs for each room can later be configured in the
Room-Manager configuration window.
Содержание RF System 2.42
Страница 1: ...Eaton RF System 2 42 Manual...
Страница 123: ...123 Eaton RF System 2015 Eaton Electrical Group State Syntax of RM to user...
Страница 193: ...193 Eaton RF System 2015 Eaton Electrical Group...
Страница 197: ...197 Eaton RF System 2015 Eaton Electrical Group 4 Now we select the desired function e g On switch on delay...
Страница 200: ...200 Eaton RF System Help 2015 Eaton Electrical Group 7 And assign the function Blinking to it...
Страница 218: ...218 Eaton RF System Help 2015 Eaton Electrical Group Step 4 Configuration of device type dimming actuator...
Страница 219: ...219 Eaton RF System 2015 Eaton Electrical Group Step 5 Configuration of device type analogue actuator...
Страница 220: ...220 Eaton RF System Help 2015 Eaton Electrical Group Step 6 Configuration of device type shutter actuator...
Страница 223: ...223 Eaton RF System 2015 Eaton Electrical Group Group settings analogue actuator...
Страница 224: ...224 Eaton RF System Help 2015 Eaton Electrical Group Group settings heating actuator...
Страница 225: ...225 Eaton RF System 2015 Eaton Electrical Group Group settings binary input battery supplied...
Страница 226: ...226 Eaton RF System Help 2015 Eaton Electrical Group Group settings binary input 230V Group settings Motion detector...
Страница 227: ...227 Eaton RF System 2015 Eaton Electrical Group Group settings Temperature input...
Страница 229: ...229 Eaton RF System 2015 Eaton Electrical Group Group settings Analogue input Group settings Impulse input...