This section provides an overview of the generator rear
panel layout, which includes panel areas dedicated to var-
ious standard system functions and options that are avail-
able. Figure 3-4 illustrates a typical panel layout.
AC Power Inlet Panel
A
IEC Power Inlet Connector – Attaches to an IEC style
power cord.
B
Power Switch – Circuit Breaker – Used to switch sys-
tem power ON and OFF.
C
Chassis Grounding Stud – Chassis connection for a
protective earth ground.
The System I/O Panel
D
System Input Connector (J2) – Connections for sys-
tem control input signals.
E
System Output Connector (J3) – Connections for sys-
tem status output signals.
F
Ultrasound Output Connector (J1) – Coaxial high volt-
age connection to ultrasonic stack.
G
Configuration Port Connector (J4) – Digital control
port to modify system parameters.
Figure 3-4
Generator Rear Panel
Options Module Panel
H
Communications Board (See NOTE below.)
Shown in the example above are these ports:
J9 - Ethernet
J10 - Serial RS-232
K
Press Interface Module (See NOTE below.)
Shown in the example above are these ports:
J6 - Base/Abort
J5
-
Thruster
J11 - Encoder
REAR VIEW PNEUMATIC PRESS/THRUSTER
J4
J1
CONFIGURATION
ULTRASOUND
SYSTEM OUTPUTS
SYSTEM INPUTS
J2
J3
J9 ETHERNET
J10 RS-232
J5 THRUSTER
J6 BASE/ABORT
J11 ENCODER
LINE VOLTAGE:
200-240 Vac
50/60Hz, 10A
PE
I
0
-WARNING-
DUKANE CORP.
POWER LINE OUTLET
MUST BE GROUNDED
DISCONNECT LINE POWER
BEFORE REMOVING COVER
ST. CHARLES IL. 60174
MADE IN U.S.A.
UL: 1012:2010
CSA: C22.2 61010-1-12
IEC: 61010-2012
C
US
U.S. PATENTS 7,475,801
7,819,158 AND 7,225,965
Rear Panel Layout Overview
A
C
B
D
E
F
G
K
H
NOTE
The press interface board is available in
several different configurations.
See
Section 9, Options
for more infor-
mation about Data Transfer using the
Communications Board and more about
the Press Interface Module.
Page 16
iQ Series
Ultrasonic Generator/Power Supply, Servo Systems, ES User’s Manual
Dukane Manual Part No. 403-587-00
Содержание ES
Страница 127: ...SECTION 8 Maintenance Page 121 Dukane Manual Part No 403 587 00 Section 8 Maintenance ...
Страница 137: ...SECTION 10 Contacting Dukane Page 131 Dukane Manual Part No 403 587 00 Section 10 Contacting Dukane ...
Страница 171: ...Index Page 165 Dukane Manual Part No 403 587 00 Index ...