background image

PC-15R WITH ENCLOSURES

PS-A15R / PS-E15R

The PS-A15R and
PS-E15R enclosures
includes a built-in
speaker and enough
room for a CE or UL
approved transformer.

The PS-A15R comes with a built-in CE
approved transformer. That is Class II Rated
(Double insulated) and contains thermal fuse
protection. Max: 125 C, 1A. See transformer
specifications below.

230 VAC ~ 50Hz, 0.14 A
16 VAC ~ 1.5A, 25 VA
CE
A1:1998
EN 61558-1:1997
EN 61558-2-6:1997

The PS-E15R is shipped without a
transformer and is designed to be powered
from an external transformer. When sold in
the United States a UL approved transformer
is recommended.

The enclosure weight and dimensions are
provided below.

182mm (7.2”) Length
80mm

(3.1”) Width

68mm

(2.7”) Depth

1.24Kg (2.7lbs) PS-A15R
0.63Kg (1.3lbs) PS-E15R

PS-A15R

PS-E15R

Input:
Output:
Certifications:
Compliance:

Dimensions:

Weight:

°

PC-15R / PS-A15R/ PS-B15R

PS-E15R / PS-F15R

POWER SUPPLY

INSTALLATION INSTRUCTIONS

INTRODUCTION & KEY FEATURES

The PC-15R Power Supply is designed for use
with all Rosslare conventional stand-alone
Access Control Units (ACU).

The power supply is also capable of driving an
external speaker that is controlled by the ACU to
annunciate the Bell tone.

COMPATIBLE CONTROLLERS

List of compatible controllers by model
number.

AC-05
AC-06
AC-07
AC-08

The PC-15R has a regulated charging circuit
designed to keep a backup 12 VDC lead acid
battery fully charged, for use in the event of a
power failure. For best results a 12 VDC battery
with up to 7 AH is recommended.

The bell button on any compatible ACU will
activate the PC-15R auxiliary output. The output
will remain active for as long as the bell button is
pushed.

A release to exit (REX) button can also be
attached to the power supply if it is required.

ROSSLARE

ELECTRICAL SPECIFICATIONS

AC Input:

DC Battery Charger:

DC Input wired to backup battery
terminals:

Lock Strike Output and Power Supply:

Controller Power Supply:

Auxiliary Output:

Power LED & Speaker Output:

16 ~ 18 VAC (1.5 A, 25 VA)

12V DC Lead Acid Battery
Up to 7AH recommended

10 - 16 VDC

Battery current draw depends
on attached devices.

5 A Relay
SPDT connection available via
terminal blocks.
12 VDC, constant voltage
1.2 A current limit.

12 VDC, constant voltage
1.2 A current limit.

Open collector, active low
50 mA max. sink current @ 12 VDC

Power LED indicator.

8 OHM, 0.25 W (Minimum)
For bell, chime and siren alerts.

ENVIRONMENTAL SPECIFICATIONS

MECHANICAL SPECIFICATIONS

WIRING RECOMMENDATIONS

PCB MOUNTING DIMENSIONS

Operating Temperature:

Operating Humidity:

Weight:

Dimensions:

(14

56 grams (0.11 lbs)

77mm (3.0”) Length
57mm (2.2”) Width
33mm (1.3”) Depth

Maximum distance between the Controller
and the PC-15R is 150m (500ft).

Lock wiring should be 20 Gage

Communication wiring (R1 & R2) should be
twisted Pair, 22 Gage, shielded or unshielded.

Dimensions for PCB mounting holes are
provided below.

-10°C to 70°C

°F to 158°F)

0 to 95% (Non-Condensing)

66mm (2.6”)

46mm

(1.8”)

Отзывы: