NOTE
The example shown in Figure 6-7
assumes trigger force for a part with
four linear inches of weld would need
between 32 - 42 lbs. of trigger force
A 20 inch linear weld may require
between 52 - 70 lbs. of trigger force.
See Figure 6-8, Initial Trigger/Force
Settings.
Figure 6-7
iQ Explorer II
, Process Settings > Trigger > Type, Force, Max Trigger Time
Figure 6-8
Suggested Initial Trigger/Force Setting
Step 5 - Specify Trigger Settings
Select
Force
as the type of trigger.
Then program the desired amount of force the press is to
apply before ultrasound is initiated.
Next, program
Max Trigger Time
. This provides a
measure of safety insuring the welder will fault if for
some reason the welder never achieves the programmed
trigger force. See Figure 6-7.
Fo
rce (pounds)
Linear Weld Joint (inches)
110
105
100
95
90
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36