4. If all the indicators pass their tests, the stack is within
the Digi-Trac range.
The generator is operating at the optimum setting
for this stack when the Watts displayed on the graph
(after the test) is less than the typical 200 Watts of
power. The vibration amplitude of the horn and
booster and the mass of the horn determine the
amount of power needed to vibrate the stack.
•
If the system passes the tests of these four steps,
proceed to the section called
Cycling the System
,
on Page 119.
• If one or more of these tests have failed, go to
the next step.
Figure 7-2
i
Q Explorer II
TEST, Screen Display
NOTE
Note the Frequency and Power values in
the graph above.
You have the option of saving the test
data for future reference.
Continued
Acoustic Stack Test
Continued from Previous Page
Figure 7-3
i
Q
Explorer II
, Alarm Detected - Cycle Stopped
Page 117
Dukane Manual Part No. 403-587-00
Section 7 - System Operational Testing