Alarm Status
–
This feature is included with the Part Lim-
its menu to compliment part cycle data. It does this to show
that a system alarm (www.dukane.com/us/DL_EasyAlarm.
asp) was active during the weld cycle for a particular part.
There are four options with Alarm Status – one that disables
the feature, and three other options that allow for the part
record to show that an alarm was active.
Options:
1)
Disabled
– Alarm Status is off. If an alarm
occurs, no signal will be generated for the welded part
record.
2) and 3)
Force Bad
, or
Force Suspect
– The
ultrasonic generator will provide a signal when a system
alarm activates. The operator chooses whether to
categorize the part under this circumstance as Suspect or
as Bad. Whatever designation is given to the part, it will
be carried on to become an item in the part record.
Figure 5-31 on the right shows with the red square
symbol, that Force Bad has been chosen as the option
for Alarm Status.
4)
Display
– Whenever a system alarm happens,
the ultrasonic generator indicates this on the display's
Operate screen. A square green indicator appears
alongside the term Alarm Status. This is a visual cue
to the operator. The part record will not have this
information.
Time
–
This is the current time of day according to the
iQ
generator timer.
Date
–
This is the current date according to the
iQ
genera-
tor timer.
Setup
–
This is the number of the current setup.
Process Limits, Continued from Previous Page
Process Limits, Continued
Figure 5–31
Process Limits - Alarm Status
Page 65
Dukane Manual Part No. 403-587-00
Section 5 - Operation