Part Data Indexes
Number
Description
1
Part Number
2
Sequence Index
3
Sequence Count
4
Downstroke Time
5
Downstroke Distance
6
Average Down Velocity
7
Trigger Pressure
8
Trigger Delay Time
9
Trigger Delay Dist
10
Force At Trigger
11
Weld 1 Time
12
Weld 1 Distance
13
Weld 1 Energy
14
Weld 1 Power
15
Weld 1 Position
16
Weld Peak Force
17
Weld 2 Time
18
Weld 2 Distance
19
Weld 2 Energy
20
Weld 2 Power
21
Weld 2 Position
22
Total Weld Time
23
Total Weld Distance
24
Total Weld Energy
25
Hold Time
26
Hold Distance
27
Total Cycle Time
28
Total Stroke
50
Time Format: HH:MM:SS
51
Date -> Formats: DD/MM/YYYY, MM/DD/YYYY, YYYY/MM/DD
52
Setup Number
53
Error Code -> "U Number" without the 'U'
Table 9-I
Part Data Indexes
NOTE
Individual data
records are separated
by a comma, tab,
or semicolon. The
character used is set in
the Hardware Settings
screen. See page 74
for setting the Output
Format character.
The indexes are printed
as 4 characters '0' pad-
ded, and the entire field
size is 20 characters
including the delimiter.
The data is right justified
with spaces.
Complete cycle data re-
cord is terminated by car-
riage return and optional
line feed characters.
The format is meant to
mimic Dukane's DPC
generator protocol as
closely as possible.
Page 129
Dukane Manual Part No. 403-587-00
Section 3 - Installation
Содержание ES
Страница 127: ...SECTION 8 Maintenance Page 121 Dukane Manual Part No 403 587 00 Section 8 Maintenance ...
Страница 137: ...SECTION 10 Contacting Dukane Page 131 Dukane Manual Part No 403 587 00 Section 10 Contacting Dukane ...
Страница 171: ...Index Page 165 Dukane Manual Part No 403 587 00 Index ...