In this example, a sequence to be used in an insert ap-
plication has two segments. The first part of the sequence
is known as Setup 01 which will process four #1 inserts.
The second part of the sequence is Setup 02 which will
process four #2 inserts.
Segment 1 deals with insert #1, and Segment 2 deals with
insert #2. Each segment has four cycles. When the cycles
are finished, the sequence is reset to begin processing
another part.
The figure below
gives a graphic representation of what this
sequence might look like on an X-Y table.
Appendix C
Sequencing Notes
Setup 01, Cycle 1
Setup 02
Cycle
3
Setup 02
Cycle 2
Setup 02
Cycle 1
Setup 02
Cycle 4
Setup 01, Cycle 3
Setup 01, Cycle 4
Start Point
Stop Point
Setup 01, Cycle 2
Figure C-2
Insertion Sequence Example
Page 154
iQ Series
Ultrasonic Generator/Power Supply, Servo Systems, ES User’s Manual
Dukane Manual Part No. 403-587-00
Continued