Digital Filter Setup Menu
Avg
Averaging mode
Determines the number of samples to average
0
1 reading, not averaged.
1
Circular auto averaging, 1 reading is averaged while
weight is in motion, 4 readings while stable.
2
Circular auto averaging, 2 readings are averaged
while weight is in motion, 8 readings while stable.
4
Circular auto averaging, 4 readings are averaged
while weight is in motion, 16 readings while stable.
8
Circular auto averaging, 8 readings are averaged
while weight is in motion, 32 readings while stable.
16
Circular auto averaging, 16 readings are averaged
while weight is in motion, 64 readings while stable.
Automatic Zero Tracking Setup Menu
A2t
Automatic Zero Tracking Range
Small weights within the specified number of
divisions are automatically zeroed.
oFF
Zero tracking is off. No automatic zeroing.
0.5
Zero tracking to within 0.5 divisions.
1
*
Zero tracking to within 1.0 division.
2
*
Zero tracking to within 2.0 divisions.
3
*
Zero tracking to within 3.0 divisions.
5
*
Zero tracking to within 5.0 divisions.
10
*
Zero tracking to within 10.0 divisions.
20
*
Zero tracking to within 20.0 divisions.
* NOTE
: These items are disabled in the Legal for Trade mode.
Motion Aperture Setup Menu
nn.A.
*
Motion aperture
*
Determines how many divisions consecutive
readings must change before the scale is
considered in motion.
0.5
0.5 division change must be seen to enter motion.
1
1 division change must be seen to enter motion.
2
2 division change must be seen to enter motion.
3
3 division change must be seen to enter motion.
5
5 division change must be seen to enter motion.
10
10 division change must be seen to enter motion.
20
20 division change must be seen to enter motion.