89
Module
Terminal
Conductor Color
Relay 1
1(-) A2
Brown
Relay 2
1(-) A2
Red
Relay 3
1(-) A2
Orange
Relay 4
1(-) A2
Yellow
Relay 5
1(-) A2
Green
Relay 6
1(-) A2
Blue
Relay 7
1(-) A2
Purple
Relay 8
1(-) A2
Grey
Power Supply
V
White
Power Supply
Output -V
Black
Table 14: Scale Signal Cable Color Code
Digital Output Setup:
Digital Output Terminal TB4 requires the jumpers at JU11 and JU19 to be removed in
order to be used with the External Relay Box option. Wiring connections for the signal
cable to the Digital Output board are shown in Fig 23 below.
Fig. 23: Digital Output Wire and Jumper locations.
Digital Output Specifications:
Each Digital output consists of a current-sinking npn Darlington pair with a transient-
suppression diode and a 10K ohm pull-up resister connected to +V.