Display Accumulator and Counter Values
Press the ACCUM button to enter the accumulator and counter recall mode. The display
will show
Accunn
followed by the accumulated weight in the units currently selected in
the weigh mode. Then
Countr
will be displayed followed by the counter value.
Press ACCUM to exit the accumulator and counter recall mode without changing their
values.
Clear Accumulator and Counter
Press the ACCUM button to enter the accumulator and counter recall mode. The display
will show
Accunn
followed by the accumulated weight in the units currently selected in
the weigh mode. Then
Countr
will be displayed followed by the counter value.
Press CLEAR to clear the accumulator and counter values. The display will show
Clr Ac
and exit from the recall mode.
Changing the current display units will clear both the accumulator and counter values.
Accumulator and Counter Data String Output to Printer or Other Device
Press ACCUM to enter the accumulator recall mode. Press PRINT to transmit the LB4
custom data string that contains the accumulator and counter values by default. Both
the accumulator and counter values are cleared after transmission.
See Output Formats in the parameter section and Custom Data String default settings
for more details.
Accumulator and Counter Operation
When a manual or automatic print function is executed, the accumulator has the
currently displayed weight added to its’ current value and the counter is incremented.
To confirm an accumulation and counter operation, the left most display digit will
momentarily display an
o
.
To automatically accumulate, select an auto print function in the parameter setup menu.
To accumulate manually, allow the scale to become stable and press PRINT.
The maximum value that can be shown for the accumulator and counter is 999,999.
When the maximum value is reached, the accumulator and counter will rollover to a zero
value. This feature can only be used in a non Legal For Trade application.
For the 2200CW model configured for 250 product memory, the Accumulator and
Counter values are stored with the associated Product ID number.