61
d3
Live Scale (Virtual) Display format,
Prints current weight, units,
annunciators, checkweigh status,
and output status.
<"^"><p><xxxx.xx><ut><an><chk1-4>
<chk5-8><out1-4><out5-8><ETX>
Sample Print String
±--10.05000000
Note: “-” represents a space
<"^">
caret (5Eh)
<p>
Weight Polarity
Negative weight printed as “-”,
positive weight is printed as a
space (20h).
<xxxx.xx>
Weight Data fixed field
of 6 digits plus decimal. In overload,
or underload “-------” is printed.
Leading zeros are printed as
spaces (20h).
<ut>
Displayed Units
lb = 0(30h), kg = 1(31h), oz =
2(32h), g = 3(33h), lb:oz = 4(34h)
<an>
Annunciators
all off = 0(30h), all on = ?(37h)
ZERO = bit 0
BATT = bit 1
MOT = bit 2
<chk1-4>
Setpoint status 1-4.
all off = 0(30h), all on = ?(3fh)
Setpt 1 = bit 0
Setpt 2 = bit 1
Setpt 3 = bit 2
Setpt 4 = bit 3
<chk5-8>
Setpoint status 5-8.
all off = 0(30h), all on = ?(3fh)
Setpt 5 = bit 0
Setpt 6 = bit 1
Setpt 7 = bit 2
Setpt 8 = bit 3
<out1-4>
Output status 1-4
all off = 0(30h), all on = ?(3fh)
out 1 = bit 0
out 2 = bit 1
out 3 = bit 2
out 4 = bit 3
<out5-8>
Output status 5-8
all off = 0(30h), all on = ?(3fh)
out 5 = bit 0
out 6 = bit 1
out 7 = bit 2
out 8 = bit 3
<ETX>
End of Text (03h)