Error Messages:
Error Message
What to Do or Check:
"
ovr Ld
" Scale overload
The scale is in overload. The load on the scale exceeds the
capacity by more than 103%. Remove excess weight from
scale.
"
udr Ld
" Scale underload
The scale is in underload. The load on the scale is less then
the minimum scale capacity by more than -20%. Recalibrate
scale or add additional dead load.
"
grS oL
" Gross overload
The scale is in gross overload. The load exceeds the scale
ratings and might result in damage to the scale. Remove
excess weight immediately. Ignore this message for the first 5
seconds after power up.
"
grS uL
" Gross underload
The scale is in gross underload. The load exceeds the
minimum scale ratings and might result in damage to the
scale. Load cell connections might be wired in reverse. Ignore
this message for the first five seconds after power up.
"
SU 0 E
" Startup zero error
The scale was not stable. This error will only occur in Legal for
Trade applications. The scale will zero once it becomes
stable.
"
Er Ad
" A/D failure
The scale has detected a failure in the A/D circuit. Have the
scale serviced by a qualified scale repair technician.
"
Er Sr
" SRAM error
The setup parameters loaded in nonvolatile memory (SRAM)
have become corrupted. The scale requires recalibration by a
qualified scale technician.
"
Err 1
" Program ROM error
The program memory in the scale has become corrupted.
Have scale serviced by a qualified scale repair technician.
"
Ldg 0
" Loading zero.
The scale is attempting to load power up zero. This message
will remain until scale is stable.
“
SPAn E
”
Calibration Range Error
Calibration zero is out of range, refer to A/D Ranging section
for additional information.
“
Er neg
”
Negative Weight Error
Weight is negative range, Load cell signal wires backwards,
refer to A/D Ranging section for additional information.
“
Er nno
”
Motion Error
Weight readings are unstable. Too much vibration occurs
during weight entry. Load cell signal wires are not connected.
“
rA Err
”
Calibration Span Error
Calibration Span is out of range, refer to A/D Ranging section
for additional information.
"
No SAV
"
Parameter value not saved.
The scale has not successfully stored or verified the parameter
value in nonvolatile memory.
"
Er Cnt
"
Count by Error.
The weight value entered has a smaller count by step than the
scale's current count by resolution.
"
Er dp
"
Decimal Point Error.
Too many digits to the right of the decimal point have been
entered for capacity.
"
CAP rg
"
Capacity Range Error.
Capacity weight entered has more than three non-zero digits in
a row.
"
CAP Lo
"
Capacity weight is too low.
Capacity weight entered is less than 1 lb or kg.