41
Printer Data Output Setup Menu
d.o.
Data Output Mode
Determines when serial data will be sent out of
serial port 1.
t.o.d.
Transmit on demand. The current stable weight is
transmitted whenever the PRINT button is pressed,
a remote PRINT button is pressed, or a print
request is received via communications options.
A.P.1
Auto Print 1 transmits the first stable weight reading
above the threshold level.
A.P.2
Auto Print 2 transmits the first stable weight reading
that is above the threshold level. Once a weight has
been transmitted, no further weights will be transmitted
until the scale returns to a weight below the threshold
level. The default setting for the threshold level is 1%
of scale capacity. To adjust the threshold level, see
the Threshold Level parameter.
A.P.3
Auto Print 3 transmits the first stable weight reading
above the threshold value, while output 6 is active.
Once a weight has been transmitted, no further
weights will be transmitted until the scale returns to a
weight below the threshold level. The default setting
for the threshold level is 1% of scale capacity. To
adjust the threshold level, see the Threshold Level
parameter.
A.P.4
The first stable weight, above the threshold, is
recorded. When the weight falls below the threshold,
this recorded weight is transmitted. No further weight is
transmitted until the weight stabilizes above the
threshold once again and the process repeats. The
default setting for the threshold level is 1% of scale
capacity. To adjust the threshold level, see the
Threshold Level parameter. Display will show a “
c
” to
indicate weight has been captured.
A.P.5
The last stable weight, above the threshold, is
recorded. When the weight falls below the threshold,
this recorded weight is transmitted. No further weight is
transmitted until the weight stabilizes above the
threshold once again and the process repeats. The
default setting for the threshold level is 1% of scale
capacity. To adjust the threshold level, see the
Threshold Level parameter.
C.P.
In continuous print, data is transmitted each time the
scale updates the weight display. Display updates that
occur while the scale is in motion are identified by the
abbreviation "MOT" following the weight data. The
Digital Filter Setup parameter controls the number of
data transmissions per second.
Note: This option is disabled in RS485 mode.