79
Operation and Output Signals
There is no effect on scale operation when the 4-20mA Analog Output Option is
installed. The only exception to this is on models with the battery option where battery
life will be reduced by 50% when the 4-20mA option is set to the active mode. To
restore battery life, set the 4-20mA option to passive.
The output signals are as follows:
The 4-20mA output is based upon the current displayed weight
Overload or Gross Overload Errors – 24mA
Underload of Gross Underload Errors – 3.5mA
Negative displayed scale weight – 3.5mA
Fig. 14.2: Example of an Active 4-20mA circuit.
Fig. 14.3: Example of a Passive 4-20mA circuit.