17
Press ZERO to momentarily display the current parameter settings and output logic for
that individual setpoint.
Change Setpoint Values
Press SET POINT to enter the setpoint edit mode. The last viewed or edited setpoint
will be displayed. Press UNITS or PRINT to scroll through the eight available setpoints.
The annunciators below the main display indicate the current setpoint.
To change the setpoint value, enter the setpoint value using the numeric keypad. Press
ENTER to accept the change and return to the weigh mode or press UNITS or PRINT to
save and edit other setpoints. Press SET POINT to exit this mode.
The display will read
abort
to indicate no changes were made to the setpoint values or
the display will read
SaVed
to indicate the setpoint value is saved.
NOTE:
On 2200B models configured for Batch Operating mode, the SET POINT button
is disabled when the batch sequence is running.
Barcode Entry of Setpoint Values
Press SET POINT to enter the Setpoint edit mode. The display will momentarily show
SEtPt
, then flash the current setpoint weight. Press UNITS or PRINT to scroll to the
desired setpoint number. The annunciators below the main display indicate which
setpoint is currently displayed.
Using Doran’s optional barcode scanner, scan the desired barcode. The display will
read
SAVEd
to indicate the scanned setpoint weight is saved. The display will flash the
new setpoint weight scanned from the barcode. No special serial commands are needed
prior to the weight data in barcode value. The barcode value must not exceed the
indicator's count by resolution and cannot be greater than the capacity. The barcode
value can be read into each of the eight available setpoints. To exit the edit mode, press
the SET POINT button.
Display Preact Values
Press and hold the SET POINT button for three seconds to display the Preact weight
values. The last viewed or edited preact will be displayed. Press UNITS or PRINT to
scroll through the eight available setpoints. The annunciators below the main display
indicate the current setpoint. Press SET POINT to exit this mode, the display will read
abort
to indicate no changes were made to the setpoint values.
Press ZERO to momentarily display the current parameter settings and output logic for
that individual preact.
NOTE:
On 2200B models configured for Batch Operating mode, the SET POINT button
is disabled when the batch sequence is running.