94
devices with the proper IP settings. Highlight the Ethernet device by clicking on it and
the device settings will be shown in the Details window on the left of the program
window. The device will show that it is configured and the IP address status will be
shown to be DHCP or Static. Be sure that the device does not have a red exclamation
mark next to it in the main window. A red exclamation mark indicates that the device
can be configured, but does not have the correct IP address required to communicate
with your pc for data collection and scale configuration purposes. If necessary,
reconfigure the scale with the proper IP Address, Subnet Mask and Default Gateway. If
the network connection icon is displayed as shown in the Digi Device Discovery screen
shot above, you can communicate with the scale from your PC.
Module LED Description
The Wired Ethernet module has two types of LEDs.
Amber (Yellow) LED
, located top left on module indicates Network link status. Off - No
electrical connection to network. On - Electrical connection to network.
Green LED
, located top right on module. Normally off, blinks to indicate network activity.