14
The scale can be zeroed while in the net mode. Press ZERO and the scale will return to
the gross mode and will zero out any weight on the scale platform. The stored tare
value will remain in memory.
The indicator is equipped with a Zero on Demand parameter, which saves the ZERO
push button command and zeroes the scale upon the next stable reading. This option
may be activated during the scale setup procedure.
NOTE:
On 2200B models configured for Batch Operating mode, the ZERO button is
disabled when the batch sequence is running.
Push Button Tare
To use Push Button Tare, simply place the tare item on the scale platform and press
TARE. The scale will store the tare weight of the item. The net weight is displayed
The TARE weight will remain in memory, even if the indicator is turned off.
NOTE:
On 2200B models configured for Batch Operating mode, the push button tare
function is disabled when the batch sequence is running.
Digital Tare Entry
Enter the tare weight value through the numeric keypad, press TARE to save the tare
weight. After the tare weight is stored, the scale will show the net weight.
The tare must be a positive, non-zero weight. If any errors are made while entering the
tare weight, press CLEAR and reenter the weight.
The TARE weight will remain in memory, even if the indicator is turned off.
For the 2200CW model configured for 250 product memory, the Tare weight is stored
with the associated Product ID number.
Tare Recall
To recall the tare weight at any time, press and hold the TARE push button for 3
seconds. The display will momentarily show
tArE
, then flash the tare weight in the
currently selected units. To exit this mode press CLEAR.
Clear Stored Tare Value
To clear a tare weight, press 0 on the keypad then press TARE. This will remove the
tare from memory.
If not cleared, the TARE weight will remain in memory, even if the indicator is turned off.