16
The indicator is equipped with a Print on Demand parameter, which saves the PRINT
push button command and transmits data upon the next stable reading. This option may
be activated during the scale setup procedure. The indicator also has several automatic
print options. See the Data Communication Section for details on Further configuration.
NOTE:
On 2200B models configured for Batch Operating mode, the PRINT button is
disabled when the batch sequence is running.
Communications Menu
Use this menu to access Serial Data Output Formats, Handshaking settings, Print Buffer
function commands and Bluetooth information. To enter the menu, press and hold the
PRINT button for 3 seconds. Use the UNITS button to scroll through the communication
parameters. Press ENTER, to save the current menu setting and exit the menu. The
display will show
SAVEd
to indicate changes were made to the menu parameter. Press
CLEAR to exit the menu without saving the current menu setting.
The Communications menu parameters:
Data Output Formats for serial Port 1 "
For
.".
Data Output Formats for serial Port 2 "
Fo2
.".
Handshaking Setup for port 1 "
HS
".
Print Buffer functions "
bUFF
", See Print Buffer section.
Bluetooth module address "
bLUE a
", followed by 12 digit address.
Note: If Handshaking parameter ”
HS
“ is set to Bluetooth mode, the 12 digit Bluetooth
module address is displayed. See the Bluetooth Option for more information.
Password Protected Setpoint, Preact, (Tare and Check Limit 2200CW) Values
All values can be reviewed, but cannot be changed unless the password is deactivated.
If the password protection is activated, the display will display
pass
when the SET
POINT, (TARE, UNDER or OVER) values are changed. Enter the password and press
ENTER, the display shows
PASS
then
OFF
. Press SET POINT (UNDER or OVER) to
change or review weight values or press and hold SET POINT to edit or review preacts.
After entering the new setpoint or preact values (TARE, UNDER or OVER), press and
hold the ENTER button for 2 seconds to activate the password protection.
NOTE: If a Password number has been stored, the password protection will be activated
upon power up.
Display Setpoint Values
Press SET POINT to display the current setpoint values. The last viewed or edited
setpoint will be displayed. Press UNITS or PRINT to scroll through the eight available
setpoints. The annunciators below the main display indicate the current setpoint. Press
SET POINT to exit this mode. The display will read
abort
to indicate no changes were
made to the setpoint values.