12
LP Panelized Baghouse 684LP - 882LP
Problem
Probable Cause
Remedy
Pressure drop not in
normal operational range
Collector overloaded at dust source Check for excessive or unusual dust loading at the dust
source.
Hopper bridging
Check for proper flow at product discharge flange on filter
hopper.
Cleaning system
Verify no debris or condensation in tube length running to
gauge
Check operation of LP reverse air cleaning fan.
Check operation of LP gear box and drive.
Power circuit for sweep
arm motor trips
Interference between sweep arms
and cages
Ensure all filter cages are fully seated.
Ensure skid material is in good condition and arms rotate
freely. Replace if necessary.