42
LP Panelized Baghouse 684LP - 882LP
11. Clean-Air Outlet Plenum and Roof Section Attachment
The clean-air outlet plenum and roof assembly is ready to be installed.
1.
Apply sealant to the top flange of the Clean-Air Access Plenum section.
2. Lift and secure the combined exhaust/roof section to the Lower Plenum Access section. Bolt into place.
3.
Install all flange bolts and tighten.
4. Install the Magnehelic Gauge which is provided with a mounting plate at a remote location suitable for observation. Run two
lines of the 1/4-in poly tubing provided from the plenum connections down to the gauge. Attach the tubing to the filter at the
section flanges with the clips provided to keep it in place. Follow Field Assembly Instructions provided on the Magnehelic Pack
drawing shipped with the collector.
roof
clean-air outlet plenum
clean-air access plenum
BS1
BS2
BS3
BS4
deflector section
Clean-Air Plenum Assembly