A–2
Specifications
Environmental Specifications
The DECserver 90L is designed to operate in an office environment
or equipment room environment such as, telephone closets or satellite
equipment rooms. It is not intended to operate in an air plenum.
Operating Environment
The operating environment for the DECserver 90L is as follows:
Item
Value
Temperature
5° C to 50° C (41° F to 122 ° F)
Maximum rate of change
20° C/hr (36° F/hr)
Relative humidity
10 % to 95 % (non-condensing)
Wet-bulb temperature
32° C ( 90° F) maximum
Dew point
2° C (36° F) minimum
Altitude
Sea level to 2.4 km (8000 ft)
Air flow
Convectively cooled. A minimum of 10 cm(4 in) of
space must be provided on both ends of the unit
for adequate air flow.
Shipping Environment
The shipping environment for the DECserver 90L is as follows:
Item
Value
Temperature
-40° C to 66° C (-40 ° F to 151 °F)
Relative humidity
10 % to 95 % (non-condensing)
Altitude