Auto-configuration
|
|
devolo dLAN 200 DSpro Manual
|
62
쎲
OVLAN_LIST_IFACE_EXTB.i = [2-4095]
Private OVLANs list: External (Ethernet) interface tag list. Up to 16 values
can be configured.
12.8.4.15 Powerline Header Parameters
쎲
PLC_HEADER_EXTA = [0-1]
쎲
Powerline header extension. Default value: 0. The two peers must be con-
figured in the same way.
쑗
0: The PLC header is not sent/received.
쑗
1: Forces external interface A to keep the powerline header for outgoing
traffic.
쎲
PLC_HEADER_EXTB = [0-1]
Powerline header extension for interface B. Default value: 0.
N
OTE
:
These parameters configure the PLC out format of the external inter-
faces. Changing these parameters on the fly can cause loss of connection
so the autoconfiguration of those parameters does not imply the use of that
configuration. The values of those parameters are stored in the NVRAM and
will be used in the next boot.
12.8.4.16 SNMP Parameters
쎲
SNMP_TRAP_IP_ADDRESS = <ddd.ddd.ddd.ddd>
Configures the IP address to which traps are sent when produced.
쎲
SNMP_TRAP_COMMUNITY_NAME = community
Configures the trap community access. This parameter is a string with maxi-
mum length 25 characters.
12.8.4.17 Multiplier Parameter
쎲
TD_MULTIPLIER = [-300, -265, -220, -190, -170, -150, -135, -125, -
115, -105, -95, -85, -80, -70, -65, - 60, -55, -50, -45, -40, -35, -30, -
25, -20, -15, -10, -5, 0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60,
65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120]
Value of gain of the time domain multiplier. The values that can be confi-
gured to go from -30dB to +12dB, allowed values are shown above. The
format in which the value is read is the value in dB multiplied by 10. The
Содержание dLAN 200 DSpro