Auto-configuration
|
|
devolo dLAN 200 DSpro Manual
|
26
12
Auto-configuration
12.1
Introduction
The following equipment is covered this document: end user CPE, intermediary
equipment of the meter room (Home Gateway, or HG), and medium voltage
equipment.
12.2
Boundary Conditions
The boundary conditions are as follows:
쐃
The network operator knows the MAC address of all equipment in the net-
work before they are e installed in the meter rooms or on the client’s premi-
ses.
쐇
Each piece of equipment has a reserved static management IP address asso-
ciated with it that is assigned by DHCP.
쐋
The network operator has stored the detailed configuration that each piece
of equipment has to receive (associated with its PLC MAC) in its Information
System prior to installation in the field. When not available, a default con-
figuration will be utilized.
쐏
The Management VLAN of all PLC equipment of a transformer station may
be different for each transformer station, even though it will be the only one
for each transformer station. (Management VLAN is understood to be that
which all hosts of the PLC equipment access for its configuration.)
쐄
The number of data VLAN_IDs per transformer station can vary. In other
words, there can be more than one data VLAN per transformer station.
쐂
The number of voice VLAN_IDs per transformer station can vary. In other
words, there can be more than one voice VLAN per transformer station.
쐆
The equipment may not be equipped with R/W memory to store all configu-
ration parameters.
쐊
Only the end users (CPEs) can hang in different transformer stations. Howe-
ver, if this CPE is not generic (meaning private VLANs or private OVLANs), it
can hang only in the correct transformer station and HG.