10 - ELECTRICAL SYSTEM
225
1
3
2
10.4 - CHARGING SYSTEM
COMPONENTS
The main elements of the charging system are:
- Magneto: This is a three-phase element generating alternating current.
- Current rectifying regulator: This has the job of rectifying the alternating current generated by the mag-
neto to direct current in order to charge the battery. In addition it regulates the voltage received by the
battery between a minimum and maximum value.
- Three-phase system with a power rating of 200W.
- DC voltage produced at the regulator output:
13 -15v at 8,000 rpm
Stator resistance between phases:
0,4 +/- 10%.
Check on the magneto side of the connector between 1, 2 and 3 (3 measurements).
- AC voltage measured between the phases at the regula-
tor input connector:
1,700 rpm (idling): 25v
5,000 rpm: 60v.
CURRENT LEAKAGE
- With the ignition key in the OFF position, connect the ammeter in series between the negative battery
terminal and the negative battery cable.
- The readout value must be less than 1mA = 0.001A.