HD31
- 120 -
V1.6
20
TECHNICAL FEATURES
Power supply
Rechargeable
3.7 V Li-ion internal battery, 2250 mA/h capacity,
3-pole JST connector.
Optional
external power supply unit (
SWD05
), to be connected to
the mini-USB connector of the instrument.
If connected to PC, it is powered from the computer’s USB port (500
mA
at least).
Battery life
18 hours of continuous operation (typical duration starting from a fully
charged battery and with 3 connected Pt100 probes).
The actual bat-
tery life depends on the number and type of connected probes
.
Logging
Manual or automatic with 1, 5, 10, 15, 30 seconds / 1, 2, 5, 10, 15,
20, 30 minutes / 1 hour configurable interval
Storage capacity
SD memory card, capacity up to 4 GB.
The logging duration depends on the number of stored quantities and on
the capacity of the SD memory card employed. E.g., with a 4 GB SD
memory card, the logging duration is of some months even if several
quantities with minimum logging interval of 1 s are recorded.
Inputs
3 inputs with 8-pole DIN45326 connector. According to the type of
connected probes, the instrument can manage up to 36 quantities.
Accuracy of the instrument
@ 20°C
± 0.02 % of the measurement
(
connected probe accuracy excluded
)
Temperature drift of the
instrument @ 20°C
20 ppm/°C
(
connected probe drift excluded
)
Long-term stability of the
instrument
0.05 %/year
(
connected probe stability excluded
)
Clock stability
1 min/month maximum deviation
Display
Graphic color LCD. Visible area 43 x 58 mm.
USB connection
1 USB port with mini-USB connector. The port can operate in “HID”
mode (no USB driver installation required) or in “Virtual COM” mode
(USB driver installation required).
RS232C
connection
1 RS232C serial output with RJ12 (6P6C) connector for connection of a
serial printer. Settable Baud Rate from 1200 to 115200.
Auto-off
Configurable after 2, 5, 10, 15, 20 or 30 minutes from the last key
pressure if battery powered. Can be disabled.
Automatically disabled with external power supply.
Operating conditions
-10 … 60 °C, 0 … 85% RH no condensation
Storage Temperature
-25 … 65 °C
Materials
ABS, 55 shore rubber protection lateral bands
55 shore rubber protective shell
Dimensions
165x88x35 mm without rubber protective shell
180x102x46 mm with rubber protective shell
Weight
About 400 g (with battery and protective shell)
Degree of protection
IP 64
The characteristics of accuracy and resolution of the instrument in line with the available SI-