VLT
®
6000 HVAC
MG.60.B1.02 - VLT is a registered Danfoss trademark
40
The table and the drawing give the measurements of
IP 00 LC filters for Compact units.
IP 00 LC filters must be integrated and protected
against dust, water and corrosive gases.
Max. motor cable length:
- 150 m screened/armoured cable
- 300 m unscreened/unarmoured cable
If EMC standards are to be complied with:
- EN 55011-1B:
Max. 50 screened/armoured cable
Bookstyle: Max. 20 m screened/armoured cable
- EN 55011-1A: Max. 150 m screened/armoured cable
A
B
C
G
E
F
D
LC filter IP 00
LC type
A [mm]
B [mm]
C [mm]
D [mm]
E [mm]
F [mm]
G [mm]
Weight [kg]
175Z4600
220
135
92
190
68
170
8
10
175Z4601
220
145
102
190
78
170
8
13
175Z4602
250
165
117
210
92
180
8
17
175Z4603
295
200
151
240
126
190
11
29
175Z4604
355
205
152
300
121
240
11
38
175Z4605
360
215
165
300
134
240
11
49
175Z4606
280
170
121
240
96
190
11
18
175Z4607
280
175
125
240
100
190
11
20
175Z4608
280
180
131
240
106
190
11
23
175Z4609
295
200
151
240
126
190
11
29
175Z4610
355
205
152
300
121
240
11
38
175Z4611
355
235
177
300
146
240
11
50
175Z4612
405
230
163
360
126
310
11
65
■
■
■
■
■