Mechanical brake control
For hoisting applications, it is necessary to be able to
control an electro-magnetic brake.
For controlling the brake, a relay output (01 or 04) is
required. This output must be kept closed (voltage-
free) during the time when the adjustable frequency
drive is not able to 'hold' the motor, due to a load that
is too large, for example. In parameter 323 or 326 (re-
lay outputs 01, 04), select
Mechanical brake control
[32] or
Extended mechanical brake control
[34] for ap-
plications with an electro-magnetic brake.
During start/stop and ramp-down, the output current is
monitored. If
Mechanical brake control
[32] is selected
and the current is below the level selected in parame-
ter 223
Warning: Low current
, the mechanical brake is
closed (voltage-free).
As a point of departure, a current can be selected
which is approx. 70% of the magnetizing current. Pa-
rameter 225
Warning: Low frequency
states the fre-
quency during ramp-down at which the mechanical
brake is to close again.
If Extended mechanical brake control [34] is selected
the mechanical brake is closed (voltage-free) during
start until the output current is above the level selected
in parameter 223
Warning: Low Current
.
During stop mechanical brake is released until the fre-
quency is below the level selected in parameter 225
Warning: Low frequency
.
Notice by
Extended mechanical brake control
[34] that
the brake does not close if the output current falls un-
der parameter 223
Warning: Low current
.
Nor does a current low level warning appear.
In extended mechanical brake mode, an overcurrent
trip (alarm 13) can be reset by an external reset.
If the adjustable frequency drive is brought into an
alarm condition or an overcurrent or overvoltage sit-
uation, the mechanical brake will immediately cut in.
NOTE
The application shown is only for hoisting
without counterweight.
Control of mechanical brake:
Parameter:
Setting:
Data value:
323
Relay 01 or par. 326 relay 04
Mechanical brake control
[32]
323
Relay 01 or par. 326 relay 04
Extended mechanical brake control
[34]
223
Warning: Low current
approx. 70% of magnetizing current
1)
225
Warning: Low frequency
3-5 Hz
2)
122
Function at stop
Pre-magnetization
[3]
120
Start delay time
0.1-0.3 sec
121
Start function
Start frequency/voltage clockwise
3)
[3]
130
Start frequency
Set to slip frequency
131
Initial voltage
The voltage must correspond to the frequency that has been set in pa-
rameter 130.
1.
During start and stop, the current limit in pa-
rameter 223 determines the switching level.
2.
This value indicates the frequency during
ramp-down at which the mechanical brake is
to be closed again. This assumes that a stop
signal has been given.
3.
It must be ensured that the motor starts clock-
wise (hoist), since otherwise the adjustable
frequency drive may drop the load. Switch U,
V, W connections, if required.
VLT
®
5000 Series
198
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
Содержание VLT 5000 Series
Страница 2: ...VLT 5000 Instruction Manual ...
Страница 3: ......
Страница 45: ...Mechanical dimensions cont VLT 5000 Series 42 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Страница 196: ...RELATIVE VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 193 List of functions ...
Страница 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 198: ...References VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 195 List of functions ...
Страница 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Страница 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 238: ...Rev 2006 12 12 www danfoss com drives 175R5271 MG51C522 MG51C522 MG51C522 VLT 5000 Instruction Manual ...
Страница 239: ......