The signal outputs can be programmed to transmit a
status signal via terminal 42 or 45 and via relay output
01 or 04 (parameter 319, 321, 323 or 326).
Description of choice:
The lower signal limit of the motor frequency, f
LOW
, is
to be programmed within the normal working range of
the adjustable frequency drive.
See drawing at parameter 223.
226
Warning: High frequency
(WARN. FREQ. HIGH)
Value:
parameter 225 - parameter 202
132.0 Hz
Function:
When the motor frequency is above the limit program-
med in this parameter, f
HIGH
, the display will indicate
FREQUENCY HIGH.
The signal outputs can be programmed to transmit a
status signal via terminal 42 or 45 and via relay output
01 or 04 (parameter 319, 321, 323 or 326).
Description of choice:
The upper signal limit of the motor frequency, f
HIGH
,
must be programmed within the normal working range
of the adjustable frequency drive.
See drawing at parameter 223.
227
Warning: Low feedback
(WARN. FEEDB. LOW)
Value:
-100,000.000 - parameter 228.
-4000.000
Function:
If the connected feedback signal gets below the value
set in this parameter, the signal outputs can be pro-
grammed to transmit a status signal via terminal 42 or
45 and via relay output 01 or 04 (parameter 319, 321,
323 or 326).
Description of choice:
Set the desired value.
228
Warning: High feedback
(WARN. FEEDB HIGH)
Value:
parameter 227 - 100,000.000
4000.000
Function:
If the connected feedback signal gets above the value
set in this parameter, the signal outputs can be pro-
grammed to transmit a status signal via terminal 42 or
45 and via relay output 01 or 04 (parameter 319, 321,
323 or 326).
Description of choice:
Set the desired value.
229
Frequency bypass, bandwidth
(FREQ BYPASS B.W.)
Value:
0 (OFF) - 100%
0 (OFF) %
Function:
Some systems call for some output frequencies to be
avoided because of resonance problems in the sys-
tem.
In parameters 230-233 these output frequencies can
be programmed for bypassing (Frequency bypass). In
this parameter (229), a bandwidth can be defined on
either side of these frequency bypasses.
The frequency bypass function is not active if par. 002
is set to
Local
and par. 013 is set to
LCP ctrl/Open
loop
or
LCP+dig ctrl/Open loop.
Description of choice:
The bypass bandwidth is set as a percentage of the
bypass frequency which is selected in parameter
230-233.
The bypass bandwidth indicates max. variation of the
bypass frequency.
Example: A bypass frequency of 100 Hz and a bypass
bandwidth of 1% are selected. In this case the bypass
frequency can vary between 99.5 Hz and 100.5 Hz i.e.
1% of 100 Hz.
VLT
®
5000 Series
= factory setting, () = display text, [] = value for use in communication via serial communication port
MG.51.C5.22 - VLT
p
is a registered Danfoss trademark.
107
Progra
mming
Содержание VLT 5000 Series
Страница 2: ...VLT 5000 Instruction Manual ...
Страница 3: ......
Страница 45: ...Mechanical dimensions cont VLT 5000 Series 42 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 185: ...VLT 5000 Series 182 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 186: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 183 EC EMC ...
Страница 196: ...RELATIVE VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 193 List of functions ...
Страница 197: ...EXTERNAL PRESET VLT 5000 Series 194 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 198: ...References VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 195 List of functions ...
Страница 202: ...VLT 5000 Series MG 51 C5 22 VLT p is a registered Danfoss trademark 199 List of functions ...
Страница 217: ...VLT 5000 Series 214 MG 51 C5 22 VLT p is a registered Danfoss trademark ...
Страница 238: ...Rev 2006 12 12 www danfoss com drives 175R5271 MG51C522 MG51C522 MG51C522 VLT 5000 Instruction Manual ...
Страница 239: ......