![Dalsa FA-80-12M1H-XX-R Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/dalsa/fa-80-12m1h-xx-r/fa-80-12m1h-xx-r_user-manual_504423063.webp)
Camera Operation
•
63
Name Space
Custom
Firmware Release
00
Visibility
Guru
Access
Read-Write
Type
Integer
Values
-127 to 127
Notes
Retrieves and sets the simple feed through correction coefficient.
Name
feedThroughCorrectionMode
Display Name
Feed Through Correction Apply
Firmware Release
00
Name Space
Custom
Visibility
Guru
Access
Read-Write
Type
Enumeration
Values
Off
- Disable feedthrough correction
On
- Enable feedthrough correction
Notes
Apply the feed through correction.
Invisible Features
Name
flatfieldAlgorithmBufferFormat
Name Space
DFNC
Firmware Release
05
Visibility
Invisible
Access
Read Only
Type
Enumeration
Values
Mono8
Notes
Each flat field coefficient is stored as an 8 bit number. This feature is used for Sapera FFC
support.
Name
flatfieldAlgorithmBufferWidth
Name Space
DFNC
Firmware Release
05
Visibility
Invisible
Access
Read Only
Type
Integer
Values
SensorWidth
Notes
The width of the flat field correction buffer in pixels. Used for Sapera FFC Support.
Name
flatfieldAlgorithmBufferHeight
Name Space
DFNC
Firmware Release
05
Visibility
Invisible
Access
Read Only
Type
Integer
Values
SensorHeight
Notes
The height of the flat field correction buffer in pixels. Used for Sapera FFC Support.
Name
flatfieldAlgorithmGainDivisor
Name Space
DFNC
Содержание FA-80-12M1H-XX-R
Страница 1: ...Falcon2 Camera User s Manual 4M 8M and 12M Area Imaging P N 03 032 20107 04 www teledynedalsa com ...
Страница 14: ...14 The Falcon2 Cameras Figure 3 Quantum Efficiency INSERT QE GRAPH HERE ...
Страница 17: ...The Falcon2 Cameras 17 Mechanicals Figure 5 Camera Mechanical ADD MECHANICAL PDF HERE ...
Страница 53: ...Camera Operation 53 Figure 19 Advanced Processing Control ...